Share:


Sanwa Denki vacuum switch SVS-1

Capacitance
AC 250V 2.5A DC 100V 0.5A
AC 125V 5A DC24V 2.5A
Outline drawing of SVS-1
Main material
Pressure receiving part
(wetted part)
Zinc alloy die casting
Stainless steel
Brass
Pressure receiving element
(wetted part)
Multistage bellows
(stainless steel, phosphor bronze)
stainless steel bellows
cover Polycarbonate
switch body Phenolic resin molding
contact Silver, gold plating (3μ)
spring stainless
fluid For fluids such as air, gas, oil, water, and other
corrosive liquids and gases, a corrosion-resistant stainless steel pressure receiving part (liquid contact part) is available.
Contact configuration, wiring method
Wiring diagram of SVS-1
Wiring method
Terminals 1 (red) and 2 (blue)
 are ON when the degree of vacuum is high
 , and OFF when the degree of vacuum is low
Wiring method
Terminals 1 (red) and 3 (black)
 are OFF when the degree of vacuum is high
 , and ON when the degree of vacuum is low
Standard specifications Unit: kPa (mmHg)
  Lower limit adjustment range (pressure range) Open/close pressure difference Tolerance Pressure resistance Standard setting
A. 0 to -40 (0 to -300) 2.7 to 13.3 (20 to 100) ±1.3 (±10) 500 (5kg/cm²) -20 to -27 (-150 to -200)
B. -40 to -67 (-300 to -500) 6.7-40 (50-300) ±1.3 (±10) 500 (5kg/cm²) -53 to -60 (-400 to -450)
C. -67 to -100 (-500 to -750) 6.7-50 (50-400) ±1.3 (±10) 500 (5kg/cm²) -80 to -87 (-600 to -650)
As a general rule, the pressure setting is the factory setting. When ordering, please specify the operating vacuum (ON, OFF) and connection port size .
 
Capacitance
AC 250V 2.5A DC 100V 0.5A
AC 125V 5A DC24V 2.5A
Outline drawing of SVS-1
Main material
Pressure receiving part
(wetted part)
Zinc alloy die casting
Stainless steel
Brass
Pressure receiving element
(wetted part)
Multistage bellows
(stainless steel, phosphor bronze)
stainless steel bellows
cover Polycarbonate
switch body Phenolic resin molding
contact Silver, gold plating (3μ)
spring stainless
fluid For fluids such as air, gas, oil, water, and other
corrosive liquids and gases, a corrosion-resistant stainless steel pressure receiving part (liquid contact part) is available.
Contact configuration, wiring method
Wiring diagram of SVS-1
Wiring method
Terminals 1 (red) and 2 (blue)
 are ON when the degree of vacuum is high
 , and OFF when the degree of vacuum is low
Wiring method
Terminals 1 (red) and 3 (black)
 are OFF when the degree of vacuum is high
 , and ON when the degree of vacuum is low
Standard specifications Unit: kPa (mmHg)
  Lower limit adjustment range (pressure range) Open/close pressure difference Tolerance Pressure resistance Standard setting
A. 0 to -40 (0 to -300) 2.7 to 13.3 (20 to 100) ±1.3 (±10) 500 (5kg/cm²) -20 to -27 (-150 to -200)
B. -40 to -67 (-300 to -500) 6.7-40 (50-300) ±1.3 (±10) 500 (5kg/cm²) -53 to -60 (-400 to -450)
C. -67 to -100 (-500 to -750) 6.7-50 (50-400) ±1.3 (±10) 500 (5kg/cm²) -80 to -87 (-600 to -650)
As a general rule, the pressure setting is the factory setting. When ordering, please specify the operating vacuum (ON, OFF) and connection port size .
 

 Inquiry - Sanwa Denki vacuum switch SVS-1